Cass Technology CASTLE S SERIES Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Sicherheitstürsteuerungen Cass Technology CASTLE S SERIES herunter. Cass Technology CASTLE S SERIES Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1

w w w.castle.com.my

Seite 2 - Contents

8SmartGuard Pro - Remote can monitor and control up to a maximum of 128 doors. The controlling can also be done on the controller itself.The users can

Seite 3 - Technology

Computer Requirements :SmartGuard Standard / Pro / Pro-Remote 1. Microsoft W indows 9x or NT4 (Workstation or Server) or higher2. PCAT witha. Celer

Seite 4 - Technical Specifications

10Controls up to maximum 8 gates or barriers ( 4 entry & 4 entry ) per controllerCard only operation5,000 cards storage and 2,500 event transactio

Seite 5

Lift Access Control (SL-Series)The Castle 2SL is an expandable lift access system. It can be configured to control floor accessibility up to 16 floors

Seite 6

User Friendly.Runs on Windows NT4 and above. (Well-known stable platform for critical W indows Application)Controls Access Control, Alarm Monitoring ,

Seite 7

2) C TA 32 - 32 LED Driver / 4 Digital Inputs / 2 Relay Outputs Board 32 LED Driver and 4 digital inputs and 2 RelayOutputs Board. Connect to the FEP

Seite 8 - SmartGuard Series Software

Simple operation Housed in sturdy metal casing coated with epoxy to prevent vandalism Tubular cam lock for locking front casing Attractive and easy t

Seite 9 - SmartGuard Series Softwares

vi) Total Late In time of an employee for the monthvii) Total W orked Time of a department for the monthviii) Can generate top 10 late in staf f li

Seite 10

FingerPrint SystemHigh speed MCU running at 24MHz512Kbyte SRAMOn board battery backed Memory and RT C100 Time Sets each with 3 intervals100 Time Zones

Seite 11 - LAN / WAN Network

Castle Electronic Safe (CES)17Dimensions Height W idth DepthExternal 338mm (13.3 ) 438mm (17.2 ) 380mm (15 )Internal 238mm (9.4 ) 378mm (14.9 ) 26

Seite 12 - Ordering Information

IntroductionStandalone Door AccessNetworking Door AccessSmartGuard Series SoftwaresCar Park Access ControlLift Access ControlAlarm Monitoring System (

Seite 13 - System Configuration Diagram

RCass Technology Sdn Bhd[ 338857 - X ]No.28 Jalan PJU 3/48, PJU 3, Sunway Damansara Industrial Park, 47810 Petaling Jaya, Selangor Darul Ehsan, Malays

Seite 14

1IntroductionPlugs Into a New Era ofTechnologyPROX BYAs the leading building security solutions provider, we offer cutting edged software and hardware

Seite 15

2Features 12 keys polycarbonate keypad 3 LEDs for Valid, Error and Ready status indication One relay output for door lock system Door sensor input

Seite 16 - Time Attendance

3System ConfigurationCastle - KnightExit Push ButtonDoorDoor SensorElectro Magnetic LockPower Supply( +12Vdc )13 Amp W all PlugOrdering InformationSto

Seite 17

4Controller Models S-Series - 2/4/8 doors per controller ( CAS-2S/4S/8S )Advanced - Series -12/16 doors per controller ( CAS-12S/16S )Microprocessor M

Seite 18 - FingerPrint System

5Model / Features Control Card Events Time sets TimeZone Userup to Strorage transaction(3 intervasl (7 days+2 holidaysaccessibilityeach) / time zone)C

Seite 19 - Castle Electronic Safe (CES)

6PC Bundled withSmartGuard AccessControl SoftwareCPC-30Power SupplyRS232Com1/Com2(Max. 1Km)2 Wires RS485PCIControllerCastle-S/K/L SeriesCenturionBus 2